closed

Probleme timing sur les Basic Parameters

Added by Veronique bouzid over 10 years ago. Updated almost 9 years ago.

Status:
Closed
Priority:
High
Category:
-
Target version:
-
Start date:
21/07/2014
Due date:
% Done:

0%

Estimated time:
revision:
r0

Description

Sur pc-coillot, j'ai ecrit un petit script qui se joue en normal mode (/home/validation/SCRIPT/just_normal_mode.py pour analyser le timing des Basic Parameters.

Les fichiers resultants se trouvent dans le répertoire /home/validation/2014_07_21.

Voici le timing observé des BP: 4s pour les BP1 et 20 sec pour les BP2
14:13:54.070467, TC_LFR_ENTER_MODE (CP_LFR_MODE=1)
14:13:54.165007, TM_LFR_TC_EXE_SUCCESS, TIME=0x80000000c778 - debut du mode donc de l acquisition !!!!
14:13:55.657044, TM_LFR_HK, TIME=0x8000000241c2
14:13:58.257183, TM_LFR_SCIENCE_NORMAL_BP1_F0, TIME=0x80000004c4cb - premier BP1 (4s)
14:13:58.257588, TM_LFR_SCIENCE_NORMAL_BP1_F1, TIME=0x80000004b785
14:13:58.257965, TM_LFR_SCIENCE_NORMAL_BP1_F2, TIME=0x80000003c853 mais ici c est plutot < 4s
14:13:58.657036, TM_LFR_HK, TIME=0x8000000541bc
14:14:02.257154, TM_LFR_SCIENCE_NORMAL_BP1_F0, TIME=0x80000008c4cb
14:14:02.257527, TM_LFR_SCIENCE_NORMAL_BP1_F1, TIME=0x80000008b785
14:14:02.257856, TM_LFR_SCIENCE_NORMAL_BP1_F2, TIME=0x80000007c853
14:14:02.657031, TM_LFR_HK, TIME=0x8000000941bf
14:14:06.257147, TM_LFR_SCIENCE_NORMAL_BP1_F0, TIME=0x8000000cc4cb
14:14:06.257514, TM_LFR_SCIENCE_NORMAL_BP1_F1, TIME=0x8000000cb785
14:14:06.257827, TM_LFR_SCIENCE_NORMAL_BP1_F2, TIME=0x8000000bc853
14:14:06.657034, TM_LFR_HK, TIME=0x8000000d41c0
14:14:10.257145, TM_LFR_SCIENCE_NORMAL_BP1_F0, TIME=0x80000010c4cb
14:14:10.257519, TM_LFR_SCIENCE_NORMAL_BP1_F1, TIME=0x80000010b785
14:14:10.257832, TM_LFR_SCIENCE_NORMAL_BP1_F2, TIME=0x8000000fc853
14:14:10.657037, TM_LFR_HK, TIME=0x8000001141c2
14:14:14.257321, TM_LFR_SCIENCE_NORMAL_BP1_F0, TIME=0x80000014c4cb
14:14:14.25849, TM_LFR_SCIENCE_NORMAL_BP1_F1, TIME=0x80000014b785
14:14:14.25904, TM_LFR_SCIENCE_NORMAL_BP2_F1, TIME=0x80000014b785 - premier BP2 (environ 20s)
14:14:14.259839, TM_LFR_SCIENCE_NORMAL_BP1_F2, TIME=0x80000013c853
14:14:14.26037, TM_LFR_SCIENCE_NORMAL_BP2_F2, TIME=0x80000013c853

Paul peux-tu vérifier que ces timing sont corrects. La périodicité des 4s pour les BP1 semblent etre respectées pour chaque Fx.Par contre pour le premier BP , est ce correct.

Une fois que nous serons sur que les BP sont correctement générés, on pourra
- tester la commutaion de mode
- tester l'envoi d une UPDATE_TIME

Idem