Update APB_TIME_MANAGEMENT : If LFR is desynchronized, the LFR is resynchronized only if there is a tick (or soft_tick) and a new TCU The TCU is a vector of 31 bits (30 downto 0). Now, there is a ctrl bit to soft reset the apb_time_management. After a reset (and a soft reset), the APB_TM is desynchronized and the CT value is 0x80000000.

File last commit:

r261:489b6615789a martin
r336:d05a1ff29f0e (MINI-LFR) WFP_MS-0-1-9 JC
Show More
Bridge.vhd
52 lines | 1.2 KiB | text/x-vhdl | VhdlLexer
-- Bridge.vhd
library IEEE;
use IEEE.std_logic_1164.all;
use IEEE.numeric_std.all;
entity Bridge is
port(
clk : in std_logic;
raz : in std_logic;
EmptyUp : in std_logic;
FullDwn : in std_logic;
WriteDwn : out std_logic;
ReadUp : out std_logic
);
end entity;
architecture ar_Bridge of Bridge is
type etat is (e0,e1);
signal ect : etat;
begin
process(clk,raz)
begin
if(raz='0')then
WriteDwn <= '1';
ReadUp <= '1';
ect <= e0;
elsif(clk'event and clk='1')then
case ect is
when e0 =>
WriteDwn <= '1';
if(EmptyUp='0' and FullDwn='0')then
ReadUp <= '0';
ect <= e1;
end if;
when e1 =>
ReadUp <= '1';
WriteDwn <= '0';
ect <= e0;
end case;
end if;
end process;