##// END OF EJS Templates
Update APB_TIME_MANAGEMENT :...
Update APB_TIME_MANAGEMENT : If LFR is desynchronized, the LFR is resynchronized only if there is a tick (or soft_tick) and a new TCU The TCU is a vector of 31 bits (30 downto 0). Now, there is a ctrl bit to soft reset the apb_time_management. After a reset (and a soft reset), the APB_TM is desynchronized and the CT value is 0x80000000.

File last commit:

r219:df1aff8cd31b alexis
r336:d05a1ff29f0e (MINI-LFR) WFP_MS-0-1-9 JC
Show More
Serial_driver.vhd
62 lines | 1.3 KiB | text/x-vhdl | VhdlLexer
-- Serial_driver.vhd
library IEEE;
use IEEE.std_logic_1164.all;
use IEEE.numeric_std.all;
entity Serial_driver2 is
generic(Sz : integer := 8);
port(
Sclk : in std_logic;
rstn : in std_logic;
Sdata : in std_logic;
Gate : in std_logic;
NwDat : out std_logic;
Data : out std_logic_vector(Sz-1 downto 0)
);
end entity;
architecture arSerial_driver2 of Serial_driver2 is
signal DataR : std_logic_vector(Sz-1 downto 0);
signal DataCnt : integer range 0 to Sz-1 :=0;
signal DataCntR : integer range 0 to Sz-1 :=0;
begin
process(rstn,Sclk)
begin
if rstn = '0' then
DataR <= (others=>'0');
NwDat <= '0';
elsif Sclk'event and Sclk ='1' then
DataCntR <= DataCnt;
if DataCntR = Sz-1 then
NwDat <= '1';
Data <= DataR;
else
NwDat <= '0';
end if;
if Gate ='1' then
DataR <= DataR(Sz-2 downto 0) & Sdata;
if DataCnt = Sz-1 then
DataCnt <= 0;
else
DataCnt <= DataCnt +1;
end if;
else
DataCnt <= 0;
end if;
end if;
end process;