Bug #978
closedMauvais nombre de FFT retiré lors du filtrage PAS
0%
Description
Le requirement SSS dit :
SSS-CP-EQS-761
If SY_LFR_PAS_FILTER_ENABLED is set to enabled, the LFR flight software shall filter its
spectral matrixes according to:
The perturbation duration SY_LFR_PAS_FILTER_TBAD,
The modulus of the coarse time defining the perturbation instant
SY_LFR_PAS_FILTER_MODULUS,
The offset added for computing the perturbation instant SY_LFR_PAS_FILTER_OFFSET,
The time-shift relatively to the timecode occurrence identifying the perturbation start
SY_LFR_PAS_FILTER_SHIFT,
and by taking into account the maximum amount of non-perturbated data for F0, F1 and F2.
OR
il faudrait plutôt lire :
and by taking into account the maximum amount of non-perturbated data for F0, F1 and F2 AND by removing the TOTAL amount of pertubated data
Concrètement cela se traduit par le test case SVS-1203 (voir pdf en PJ, section B, test SVS-1203):
une perturbation de 1s à 16Hz à cheval sur la 1ere seconde avec les paramètre par défaut fait que seul la moitié de la perturbation est retirée.
Vu avec Thomas : il faudrait qu'une FFT soit retirée dès qu'elle contient des points pollués.