Project

General

Profile

Actions

Bug #910

closed

HK_LFR_DPU_SPW_LINK_STATE: ERROR_WAIT = 1

Added by Veronique bouzid about 7 years ago. Updated about 7 years ago.

Status:
Closed
Priority:
Normal
Category:
-
Target version:
-
Start date:
18/01/2017
Due date:
% Done:

0%

Estimated time:
revision:
r0

Description

Le script utilisé est /home/validation/SCRIPT/R3+/just_hk_survey.py.

Extrait de la trace
15:05:37.397922, TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=51, (PACKET_SEQUENCE_CONTROL=0xc033), PACKET_LENGTH=129, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x80000035222c, PA_LFR_HK_REPORT_SID: LFR_HK_SID = 1, HK_LFR_MODE: STANDBY = 0, HK_LFR_DPU_SPW_ENABLED: ENABLED = 1, HK_LFR_DPU_SPW_LINK_STATE: ERROR_WAIT = 1, SPARE=0x0,

et ceci durant tout le fichier.

--> QUID et observes tu cela sur ta mini-lfr
Pour info,
- version 3.1.0.2 et vhdl 1.1.89 HK_LFR_DPU_SPW_LINK_STATE: RUN = 5
- version 3.1.0.4 et vhdl 1.1.91 et vhdl 3.1.91 HK_LFR_DPU_SPW_LINK_STATE: RUN = 5

Le problème apparait depuis la version 3.1.0.5 et vhdl 3.1.91.

Les fichiers (2017_01_17-15_05_46*) sont rangés dans le répertoire /home/validation/data/R3+/3.1.0.6/3.1.91/TESTS-UNITAIRES/just_hk.

Contexte du test
----------------
FSW 3.1.0.6
VHDL 3.1.91
PFM sans Timegen
SocExplorerEngine.getSocExplorer: Version = 0.7.0, Branch = 0.6, Changeset = c459540a6dbd+
StarDundee

Actions #1

Updated by paul leroy about 7 years ago

Bug corrigé, il s'agissait d'un masque incorrect (effet collatéral de l'interdiction d'uiliser des valeurs littérales dans le code).
Il fallait avoir

#define STATUS_WORD_LINK_STATE_BITS         0x07    // [0000 0111]

au lieu de
#define STATUS_WORD_LINK_STATE_BITS         0x03    // [0000 0111]

Je corrige pour fsw >= 3.1.0.7

Actions #2

Updated by paul leroy about 7 years ago

  • Assignee changed from paul leroy to Veronique bouzid
Actions #3

Updated by Veronique bouzid about 7 years ago

  • Status changed from New to Closed

Bug corrigé en 3.1.0.7.
Le script utilisé est /home/validation/SCRIPT/just_hk_survey.py.

la trace montre que le champ HK_LFR_DPU_SPW_LINK_STATE est bien positionné à 5.

10:00:37.755202, TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=129, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x80000002222e, PA_LFR_HK_REPORT_SID: LFR_HK_SID = 1, HK_LFR_MODE: STANDBY = 0, HK_LFR_DPU_SPW_ENABLED: ENABLED = 1, HK_LFR_DPU_SPW_LINK_STATE: RUN = 5, SPARE=0x0,

et durant le test cette valeur n est pas modifiée.

Les fichiers de log ( 2017_02_03-10_01_06*) sont rangés dans le répertoire
/home/validation/data/R3+/3.1.0.7/1.1.91/TESTS-UNITAIRES/just_hk

Contexte du test
----------------
FSW 3.1.0.7
VHDL 1.1.91
EM1 sans Timegen
SocExplorerEngine.getSocExplorer: Version = 0.7.0, Branch = 0.6, Changeset = c459540a6dbd+
StarDundee

Actions