Bug #71
closedInitialisation de SEQUENCE_CNT des TM_LFR_*
0%
Description
Suite au démarage (HW&SW), on obtient les traces:
10:55:39.444599, TC_LFR_LOAD_COMMON_PAR, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=2802, (PACKET_SEQUENCE_CONTROL=0xcaf2), PACKET_LENGTH=7, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=1, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=1, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: LOAD_COMMON_PARAMETERS = 11, SOURCE_ID: MISSION_TIMELINE = 110, SPARE = 0x0, SY_LFR_BW = 1, SY_LFR_SP0 = 0, SY_LFR_SP1 = 0, SY_LFR_R0 = 0, SY_LFR_R1 = 0, CRC = 0x818d
10:55:39.446617, TM_LFR_TC_EXE_SUCCESS, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: ACKNOWLEDGE = 1, (PACKET_ID=0xcc1), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=13, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: TELECOMMAND_VERIFICATION = 1, SERVICE_SUBTYPE: TC_EXECUTION_COMPLETION_SUCCESS = 7, DESTINATION_ID: MISSION_TIMELINE = 110, TIME=0x800003adf1b9, PA_RPW_TELECOMMAND_PKT_ID=0x1ccc, PA_RPW_PKT_SEQ_CONTROL=0xcaf2
Le champ SEQUENCE_CNT correspond à la valeur initiale incrémentée de 1, d'après la SSS.
L'initialisation étant à 0, n attend donc un première valeur à 1.
Contexte:
LPPMON: Version=0.2.2 Branch=default Changeset=835955994d5f
Carte mini-LFR: LFR-172200 dev V1.0; No série III (sans connecteurs sub-click)
Vhdl: mini-lfr_0.0.0.15
Brique Star-Dundee S/N 46120065.
Soft:1.0.0.1 (variante sur carte finale)
TEST CASE = SVS_0019
Req: SSS-CP-FS-590
RPW-SYS-MEB-LFR-ICD-00097 Issue2_Rev0
RPW-SYS-SSS-00013-LES + Annex_Release_Definition Issue2_rev1