Project

General

Profile

Actions

Bug #707

closed

R3+ : dans TM_LFR_PARAMETER_DUMP toutes les valeurs relatives aux RW et PAS FILTER sont à 0 au démarrage

Added by bruno katra almost 8 years ago. Updated over 7 years ago.

Status:
Closed
Priority:
High
Category:
-
Target version:
-
Start date:
20/06/2016
Due date:
% Done:

0%

Estimated time:
revision:
r0

Description

Testé en 3.1.0.2, concerne les champs suivants :
SY_LFR_PAS_FILTER_ENABLED
SY_LFR_PAS_FILTER_MODULUS
SY_LFR_PAS_FILTER_TBAD
SY_LFR_PAS_FILTER_OFFSET
SY_LFR_PAS_FILTER_SHIFT
SY_LFR_SC_RW_DELTA_F
PA_LFR_RW_MASK_F0_WORD1
PA_LFR_RW_MASK_F0_WORD2
PA_LFR_RW_MASK_F0_WORD3
PA_LFR_RW_MASK_F0_WORD4
PA_LFR_RW_MASK_F1_WORD1
PA_LFR_RW_MASK_F1_WORD2
PA_LFR_RW_MASK_F1_WORD3
PA_LFR_RW_MASK_F1_WORD4
PA_LFR_RW_MASK_F2_WORD1
PA_LFR_RW_MASK_F2_WORD2
PA_LFR_RW_MASK_F2_WORD3
PA_LFR_RW_MASK_F2_WORD4

Actions #1

Updated by bruno katra almost 8 years ago

  • Subject changed from R3+ : dans TM_LFR_PARAMETER_DUMP toutes les valeurs relatives aux RW et PAS FILTER sont à 0 to R3+ : dans TM_LFR_PARAMETER_DUMP toutes les valeurs relatives aux RW et PAS FILTER sont à 0 au démarrage
Actions #2

Updated by paul leroy almost 8 years ago

Exact, mea culpa. Mise à jour effectuée pour fsw >= 3.1.0.3

Actions #3

Updated by paul leroy almost 8 years ago

  • Status changed from New to Resolved
  • Assignee changed from paul leroy to bruno katra
Actions #4

Updated by Veronique bouzid over 7 years ago

  • Status changed from Resolved to Feedback
  • Assignee changed from bruno katra to paul leroy
  • Priority changed from Normal to High

Bug partiellement corrigé en 3.1.0.4.
Le champ SY_LFR_PAS_FILTER_SHIFT n'est pas initialisé avec la valeur par défaut de l'ICD.
On devrait avoir 0.5 comme valeur et on a 1.0.

Les fichiers (2016_08_19-11_13_58*) sont rangés dans le répertoire /home/validation/data/R3+/3.1.0.4/TESTS-UNITAIRES/set_load_filter.
Les champs décrits ci-dessous sont bons
SY_LFR_PAS_FILTER_ENABLED
SY_LFR_PAS_FILTER_MODULUS
SY_LFR_PAS_FILTER_TBAD
SY_LFR_PAS_FILTER_OFFSET
SY_LFR_SC_RW_DELTA_F
PA_LFR_RW_MASK_F0_WORD1
PA_LFR_RW_MASK_F0_WORD2
PA_LFR_RW_MASK_F0_WORD3
PA_LFR_RW_MASK_F0_WORD4
PA_LFR_RW_MASK_F1_WORD1
PA_LFR_RW_MASK_F1_WORD2
PA_LFR_RW_MASK_F1_WORD3
PA_LFR_RW_MASK_F1_WORD4
PA_LFR_RW_MASK_F2_WORD1
PA_LFR_RW_MASK_F2_WORD2
PA_LFR_RW_MASK_F2_WORD3
PA_LFR_RW_MASK_F2_WORD4

Actions #5

Updated by Veronique bouzid over 7 years ago

ATTENTION: UN AUTRE CHAMP EST EGALEMENT MAL INITIALISE

Le champ SY_LFR_PAS_FILTER_DELTA_F n'est pas initialisé à la valeur par défaut (0.025 pour ICD 4.1). En clair il contient n importe quoi.

11:13:36.652458, TM_LFR_PARAMETER_DUMP, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: DUMP = 6, (PACKET_ID=0xcc6), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=141, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: PARAMETER_DUMP = 32, DOE_SPARE=0x0, SY_LFR_PAS_FILTER_ENABLED: DISABLED = 0, SY_LFR_PAS_FILTER_MODULUS=4, SY_LFR_PAS_FILTER_TBAD=1061109567, SY_LFR_PAS_FILTER_OFFSET=0, SY_LFR_PAS_FILTER_SHIFT=1061109567, SY_LFR_PAS_FILTER_DELTA_F=257701985340, PA_LFR_RW_MASK_F0_WORD1=0xffffffff, PA_LFR_RW_MASK_F0_WORD2=0xffffffff, PA_LFR_RW_MASK_F0_WORD3=0xffffffff, PA_LFR_RW_MASK_F0_WORD4=0xffffffff, PA_LFR_RW_MASK_F1_WORD1=0xffffffff, PA_LFR_RW_MASK_F1_WORD2=0xffffffff, PA_LFR_RW_MASK_F1_WORD3=0xffffffff, PA_LFR_RW_MASK_F1_WORD4=0xffffffff, PA_LFR_RW_MASK_F2_WORD1=0xffffffff, PA_LFR_RW_MASK_F2_WORD2=0xffffffff, PA_LFR_RW_MASK_F2_WORD3=0xffffffff, PA_LFR_RW_MASK_F2_WORD4=0xffffffff, SPARE8_3=0x0

le fichier de log (2016_08_19-11_13_58*) est dans le répertoire /home/validation/data/R3+/1.1.89/TESTS-UNITAIRES/set_load_filter.

Actions #6

Updated by paul leroy over 7 years ago

  • Assignee changed from paul leroy to Veronique bouzid

La mauvaise initialisation venait d'une erreur dans la fonction floatToChar (relevée dans une autre issue Redmine il me semble), utilisée exclusivement pour initialiser les paramètres

SY_LFR_PAS_FILTER_TBAD
SY_LFR_PAS_FILTER_SHIFT
SY_LFR_SC_RW_DELTA_F

Correction effectuée pour fsw >= 3.1.0.5

Actions #7

Updated by Veronique bouzid over 7 years ago

Bug corrigé en 3.1.0.6.

Le script utilisé est /home/validation/SCRIPT/R3+/set_load_filter_par.py.

Extrait du fichier 2017_01_18-09_00_41-Detail.txt
--> Vérification des valeurs par défaut

09:00:19.84812, TC_LFR_DUMP_PAR, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=12532, (PACKET_SEQUENCE_CONTROL=0xf0f4), PACKET_LENGTH=5, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=1, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=1, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: DUMP_PARAMETERS = 31, SOURCE_ID: MISSION_TIMELINE = 110, CRC = 0x24d4

09:00:19.855365, TM_LFR_PARAMETER_DUMP, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: DUMP = 6, (PACKET_ID=0xcc6), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=141, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: PARAMETER_DUMP = 32, DESTINATION_ID: MISSION_TIMELINE = 110, TIME=0x800000056cc6, PA_LFR_HK_SID: LFR_DUMP_SID = 10, SPARE=0x0, SY_LFR_BW=1, SY_LFR_SP0=0, SY_LFR_SP1=0, SY_LFR_R0=0, SY_LFR_R1=0, SY_LFR_R2=0, SY_LFR_N_SWF_L=2048, SY_LFR_N_SWF_P=300(s), SY_LFR_N_ASM_P=3600(s), SY_LFR_N_BP_P0=4(s), SY_LFR_N_BP_P1=20(s), SPARE=0x0, SY_LFR_N_CWF_LONG_F3=0, SPARE=0x0, SY_LFR_B_BP_P0=1(s), SY_LFR_B_BP_P1=5(s), SY_LFR_S1_BP_P0=0.25(s), SY_LFR_S1_BP_P1=1(s), SY_LFR_S2_BP_P0=1(s), SY_LFR_S2_BP_P1=5(s), SY_LFR_FBINS_F0_WORD1=0xffffffff, SY_LFR_FBINS_F0_WORD2=0xffffffff, SY_LFR_FBINS_F0_WORD3=0xffffffff, SY_LFR_FBINS_F0_WORD4=0xffffffff, SY_LFR_FBINS_F1_WORD1=0xffffffff, SY_LFR_FBINS_F1_WORD2=0xffffffff, SY_LFR_FBINS_F1_WORD3=0xffffffff, SY_LFR_FBINS_F1_WORD4=0xffffffff, SY_LFR_FBINS_F2_WORD1=0xffffffff, SY_LFR_FBINS_F2_WORD2=0xffffffff, SY_LFR_FBINS_F2_WORD3=0xffffffff, SY_LFR_FBINS_F2_WORD4=0xffffffff, SPARE8_2=0x0, DOE_SPARE=0x0, SY_LFR_PAS_FILTER_ENABLED: DISABLED = 0, SY_LFR_PAS_FILTER_MODULUS=4, SY_LFR_PAS_FILTER_TBAD=1065353216, SY_LFR_PAS_FILTER_OFFSET=0, SY_LFR_PAS_FILTER_SHIFT=1056964608, SY_LFR_PAS_FILTER_DELTA_F=1020054733,PA_LFR_RW_MASK_F0_WORD1=0xffffffff, PA_LFR_RW_MASK_F0_WORD2=0xffffffff, PA_LFR_RW_MASK_F0_WORD3=0xffffffff, PA_LFR_RW_MASK_F0_WORD4=0xffffffff, PA_LFR_RW_MASK_F1_WORD1=0xffffffff, PA_LFR_RW_MASK_F1_WORD2=0xffffffff, PA_LFR_RW_MASK_F1_WORD3=0xffffffff, PA_LFR_RW_MASK_F1_WORD4=0xffffffff, PA_LFR_RW_MASK_F2_WORD1=0xffffffff, PA_LFR_RW_MASK_F2_WORD2=0xffffffff, PA_LFR_RW_MASK_F2_WORD3=0xffffffff, PA_LFR_RW_MASK_F2_WORD4=0xffffffff, SPARE8_3=0x0

--> SY_LFR_PAS_FILTER_ENABLED: DISABLED = 0 Note: Normal apres la sequence de boot ce champ est positionné à DISABLED
--> SY_LFR_PAS_FILTER_MODULUS=4
--> SY_LFR_PAS_FILTER_TBAD=1065353216 soit 1.0
--> SY_LFR_PAS_FILTER_OFFSET=0
--> SY_LFR_PAS_FILTER_SHIFT=1056964608 soit 0.5
--> SY_LFR_PAS_FILTER_DELTA_F=1020054733 soit 0.0.25 (conforme à 4.1)

Les fichiers (2017_01_18-09_00_41*) se trouvent dans le répertoire /home/validation/data/R3+/3.1.0.6/3.1.91/TESTS-UNITAIRES/set_load_filter

Au passage, il y avait une erreur fde mon coté dans la fonction tm_lfr_parameter_dump_analyze.py (lfrverif/icommon/icd) qui décodait mal le champ SY_LFR_SC_RW_DELTA_F.

Contexte du test
----------------
FSW 3.1.0.6
VHDL 3.1.91
PFM sans Timegen
SocExplorerEngine.getSocExplorer: Version = 0.7.0, Branch = 0.6, Changeset = c459540a6dbd+
StarDundee

Actions #8

Updated by Veronique bouzid over 7 years ago

  • Status changed from Feedback to Closed
Actions