Project

General

Profile

Actions

Support #486

open

SSS-CP-FS-340 : Design or Test

Added by Veronique bouzid over 8 years ago. Updated over 8 years ago.

Status:
Feedback
Priority:
Urgent
Assignee:
Category:
-
Target version:
-
Start date:
18/08/2015
Due date:
% Done:

0%

Estimated time:
revision:
r0

Description

Hello,
Je m'interroge sur ce requirement
SSS-CP-FS-340
The RPW Flight Software shall maintain a local time with:
− a resolution of at least SY_RPW_TIME_RESOLUTION = 1 ms and a relative accuracy of
SY_RPW_TIME_ACCURACY = 500 μs for the DAS and the three analyzers.
− a resolution of at least SY_DPU_DBS_TIME_RESOLUTION = 10 ms and a relative
accuracy of SY_DPU_DBS_TIME_ACCURACY = 1 ms for the DBS.

Il est associé dans la SRS à REQ-LFR-SRS-5300_Ed2.
Dans notre fichier SSS-SRS-SVS-compliance_matrix_LFR_V2-1.2.xlsx , il apparait comme un test SVS-0020. Le script associé
est time_resolution.py (ce qui ne correspond pas à ce qui est ecrit dans le fichier ). Le nom est internal_time_consistent.py,
qui est un script de dépouillement.

Ma question est la suivante,
Je ne vois pas comment vérifier ce requirement et pour moi, c'est un test de Design.

J ai assigné ce point à Paul et mis Bruno en observateur ainsi que moi.


Files

Actions

Also available in: Atom PDF