Project

General

Profile

Actions

Bug #482

closed

Ordre de vérification des parametres de TC_LFR_LOAD_NORMAL_PAR

Added by Veronique bouzid over 9 years ago. Updated about 9 years ago.

Status:
Closed
Priority:
Normal
Category:
SRS
Target version:
-
Start date:
10/08/2015
Due date:
% Done:

0%

Estimated time:
revision:
r0

Description

Je croyais que Paul vérifier les parametres de TC_LFR_LOAD_NORMAL_PAR dans l'ordre de leur place
SY_LFR_N_SWF_L
SY_LFR_N_SWP_P
SY_LFR_N_ASM_P
SY_LFR_N_BP_P0
SY_LFR_N_BP_P1
SY_LFR_N_CWF_LONG_F3

Ce qui est vrai si un seul parametre est faux.

Si on envoie le parametrage suivant
SY_LFR_N_ASM_P = 1s
SY_LFR_N_BP_P0 = 1s
SY_LFR_N_BP_P0 = 1s

--> on obtient bien une TM_LFR_TC_EXE_INCONSISTENT mais sur le parametre SY_LFR_N_BP_P0 et non
sur SY_LFR_N_ASM_P

17:09:45.661845, TC_LFR_LOAD_NORMAL_PAR, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=15, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=1, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=1, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: LOAD_NORMAL_PARAMETERS_1 = 13, SOURCE_ID: MISSION_TIMELINE = 110, SY_LFR_N_SWF_L = 2048, SY_LFR_N_SWP_P = 16(s), SY_LFR_N_ASM_P = 1(s), SY_LFR_N_BP_P0 = 1(s), SY_LFR_N_BP_P1 = 1(s), SPARE=0x0, SY_LFR_N_CWF_LONG_F3 = 1, SPARE=0x0, CRC = 0xab17

17:09:45.675133, TM_LFR_TC_EXE_INCONSISTENT, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: ACKNOWLEDGE = 1, (PACKET_ID=0xcc1), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=8, (PACKET_SEQUENCE_CONTROL=0xc008), PACKET_LENGTH=19, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: TELECOMMAND_VERIFICATION = 1, SERVICE_SUBTYPE: TC_EXECUTION_COMPLETION_FAILURE = 8, DESTINATION_ID: MISSION_TIMELINE = 110, TIME=0x80000a0f7f28, PA_RPW_TELECOMMAND_PKT_ID=0x1ccc, PA_RPW_PKT_SEQ_CONTROL=0xc000, PA_RPW_TC_FAILURE_CODE: WRONG_APP_DATA = 5, PA_RPW_TC_SERVICE=181, PA_RPW_TC_SUBTYPE=13, PA_RPW_BYTE_POSITION=16, PA_RPW_RCV_VALUE=1

Le script utilisé est /opt/VALIDATION_R3/lfrverif/LFR_SVS/SVS-0029/normal_mode_parameter_set.py
le fichier de log (2015_07_28-18_32_00-Detail.txt) se trouve dans /home/validation/data/R3/3.0.0.8/1.1.88/SVS-0029/BUG-XXX, XXX etant le numero de ce bug.

Contexte du test
----------------
FSW 3.0.0.8
VHDL 1.1.88
EM sans Timegen
SocExplorerEngine.getSocExplorer: Version = 0.6.2, Branch = default, Changeset = 819d0376d481