Project

General

Profile

Actions

Bug #450

closed

SSS-CP-EQS-526 non conforme par rapport à ICD >= 3.3

Added by Veronique bouzid almost 9 years ago. Updated about 8 years ago.

Status:
Closed
Priority:
Normal
Category:
-
Target version:
-
Start date:
26/06/2015
Due date:
% Done:

100%

Estimated time:
revision:
r0

Description

Ici le texte de la SSS en 3.3
Each second, the LFR flight software shall put in its periodic HK packet (TM_LFR_HK) a mean of
the 16 last values of the electric field components sampled at f3: V_f3, E1_f3, E2_f3.

Paul confirme qu'il n a pas adapté ce requirement pour etre conforme à 3.3 mais qu'il respecte celui de 2.2

Le voici
Each second, the LFR flight software shall put in its periodic HK packet (TM_LFR_HK) the
last value of the electric field components sampled at f3: V_f3, E1_f3, E2_f3.

Paul, peux-tu expliquer comment tu determines la derniere valeur at f3 de V_f3, E1_f3, E2_f3?


Files

Actions

Also available in: Atom PDF