TC_LFR_DISABLE_CALIBRATION à implémenter

Added by Gerald Saule almost 11 years ago. Updated over 9 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
20/02/2014
Due date:
% Done:

0%

Estimated time:
revision:
r98

Description

TC_LFR_DISABLE_CALIBRATION provoque un retour de TM_LFR_TC_EXE_NOT_IMPLEMENTED. Le retour spécifié est TM_LFR_TC_EXE_SUCCESS (dans le cas nominal).
Ce comportement indique fidèlement la non-implémentation du traitement de cette TC.

15:49:41.484539, TC_LFR_DISABLE_CALIBRATION, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=4040, (PACKET_SEQUENCE_CONTROL=0xcfc8), PACKET_LENGTH=5, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=0, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=0, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: DISABLE_CALIBRATION = 63, SOURCE_ID: MISSION_TIMELINE = 110, CRC = 0x45bd

15:49:41.486812, TM_LFR_TC_EXE_NOT_IMPLEMENTED, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: ACKNOWLEDGE = 1, (PACKET_ID=0xcc1), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=56, (PACKET_SEQUENCE_CONTROL=0xc038), PACKET_LENGTH=17, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: TELECOMMAND_VERIFICATION = 1, SERVICE_SUBTYPE: TC_EXECUTION_COMPLETION_FAILURE = 8, DESTINATION_ID: MISSION_TIMELINE = 110, TIME=0x80015f15bbea, PA_RPW_TC_FAILURE_CODE: FUNCT_NOT_IMPL = 42002, PA_RPW_TELECOMMAND_PKT_ID=0x1ccc, PA_RPW_PKT_SEQ_CONTROL=0xcfc8, PA_RPW_TC_SERVICE=181, PA_RPW_TC_SUBTYPE=63

(Cette issue reprend Bug #494 de pc-instru)

Contexte:

LPPMON Version=0.2.2 Branch=default Changeset=835955994d5f
Carte mini-LFR: LFR-172200 dev V1.0; No série III (sans connecteurs sub-click)
Vhdl: mini-lfr_0.0.0.15
Soft: 1.0.0.1 (variante sur carte finale)
Brique Star-Dundee S/N 46120065.

TEST CASE = SVS_0001_step03

RPW-SYS-MEB-LFR-ICD-00097 Issue2_Rev0
RPW-SYS-SSS-00013-LES + Annex_Release_Definition Issue2_rev1

Actions #1

Updated by paul leroy almost 11 years ago

  • Status changed from New to In Progress

l'implémentation de la TC requière le développement d'un module spécifique pour le VHDL

Actions #2

Updated by paul leroy almost 10 years ago

  • Status changed from In Progress to Resolved
  • Assignee changed from paul leroy to bruno katra

TC_LFR_DISABLE_CALIBRATION implémentée.
FSW >= 2.0.2.2
VHDL >= x.1.63

Actions #3

Updated by Veronique bouzid over 9 years ago

  • Status changed from Resolved to Closed

la TC est bien implémentée dans le soft 2.0.x.x.
Le comportement de la TC a été testée en 2.0.2.3 et en 3.0.0.x.
Le VHDL utilisé etant x.1.68 et x.1.83