Description
Also tracked in https://jira-lesia.obspm.fr/browse/RPWSWR-625
SSS-CP-EQS-340 Acquisition synchronization
The equipment flight software shall ensure that the waveform acquisitions are synchronized on the
second, with a precision higher than 500 μs, by using the SpaceWire time code.
LFR, TDS
E.g. with a 16 samples/second cadence, the first sample shall be taken exactly on the second and
the 17th sample exactly on the next second.
A notre niveau on mesure au mieux 800 µs sur le CWF_F2 du SBM2.
Related issues
Updated by bruno katra almost 9 years ago
- Related to Bug #581: [QR R3] [RPWSWR-625] : document de caractérisation à fournir au CNES added
Updated by paul leroy almost 9 years ago
- Assignee changed from paul leroy to bruno katra
Comment avez-vous mesurés ces 800us? Vous pouvez me mettre un plot et me décrire le test?
Updated by bruno katra over 6 years ago
La RFD 260 a été créée et livrée comme demandé par le CNES qui s'était engagé à l'accepter mais celle-ci n'a jamais été signé après le départ de Gonzalo car personne n'a vraiment repris la suite. La teleconf de décembre 2017 avec Elise a montré que le CNES n'avait pas pris connaissance de toute la livraison.
J'ai commenté le point JIRA associé.
On laisse ouvert ce point jusque signature de la RFD.
Updated by bruno katra about 6 years ago
- Status changed from New to Closed