Bug #53
closedTM_LFR_PARAMETER_DUMP incohérent avec l'ICD.
0%
Description
Les données brutes sont:
14:56:20.66118, 1L, 2L, 0L, 0L, 12L, 201L, 192L, 1L, 0L, 27L, 16L, 3L, 25L, 0L, 128L, 0L, 1L, 20L, 117L, 60L, 10L, 0L, 16L, 8L, 0L, 1L, 44L, 14L, 16L, 4L, 20L, 0L, 0L, 1L, 5L, 1L, 1L, 1L
L'outil d'analyse des TM y associe:
14:56:20.66118, TM_LFR_PARAMETER_DUMP/!\Length (byte) - Exp=36, Res=34, /!\(lfr_tm_packet_detail)
A priori, les champs (bytes) SY_LFR_S2_BP_P1 et SPARE (positions 34-35) sont omis.
Contexte:
LPPMON: Version=0.2.2 - Branch=default (Changeset=835955994d5f)
Carte mini-LFR: LFR-172200 dev V1.0; No série III (sans connecteurs sub-click)
Vhdl: mini-lfr_0.0.0.15
LFR FSW: 1.0.0.1 (variante sur carte finale)
Brique Star-Dundee S/N 46120065.
TEST CASE = SVS_0001
RPW-SYS-MEB-LFR-ICD-00097 Issue2_Rev0
RPW-SYS-SSS-00013-LES + Annex_Release_Definition Issue2_rev1
Updated by paul leroy almost 11 years ago
- Status changed from New to Resolved
Bug identifié et corrigé. rev >= 1.0.0.2
Updated by Gerald Saule almost 11 years ago
Les données brutes sont les suivantes:
14:01:58.571041, 1, 2, 0, 0, 12, 201, 192, 1, 0, 29, 16, 3, 25, 0, 0, 0, 0, 16, 165, 173, 10, 0, 16, 8, 0, 1, 44, 14, 16, 4, 20, 0, 0, 1, 5, 1, 1, 1, 5, 0
On retrouve les 4 octets d'en-tête, et les 36 octets de TM_LFR_PARAMETER_DUMP.
On interprête raisonnablement:
14:01:58.571041, TM_LFR_PARAMETER_DUMP, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: DUMP = 9, (PACKET_ID=0xcc9), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=1, (PACKET_SEQUENCE_CONTROL=0xc001), PACKET_LENGTH=29, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x00000010a5ad, PA_LFR_HK_SID: LFR_DUMP_SID = 10, SPARE=0x0, SY_LFR_BW=1, SY_LFR_SP0=0, SY_LFR_SP1=0, SY_LFR_R0=0, SY_LFR_R1=0, SY_LFR_N_SWF_L=2048, SY_LFR_N_SWF_P=300(s), SY_LFR_N_ASM_P=3600(s), SY_LFR_N_BP_P0=4(s), SY_LFR_N_BP_P1=20(s), SPARE=0x0, SY_LFR_N_CWF_LONG_F3=0, SPARE=0x0, SY_LFR_B_BP_P0=1(s), SY_LFR_B_BP_P1=5(s), SY_LFR_S1_BP_P0=0.25(s), SY_LFR_S1_BP_P1=1(s), SY_LFR_S2_BP_P0=1(s), SY_LFR_S2_BP_P1=5(s), SPARE=0x0
=>Cette issue peut être fermée.
Contexte:
LPPMON Version=0.2.2 - Branch=default - Changeset=835955994d5f
Carte mini-LFR: LFR-172200 dev V1.0; No série III (sans connecteurs sub-click)
Vhdl: mini-lfr_VHDLib206 (Carte mini-LFR)
Soft: 1.0.0.2 (variante sur carte finale) = r104
Brique Brique Star-Dundee S/N 46120065.
RPW-SYS-MEB-LFR-ICD-00097 Issue2_Rev0
RPW-SYS-SSS-00013-LES + Annex_Release_Definition Issue2_rev1
Updated by Gerald Saule almost 11 years ago
- Status changed from Resolved to Closed
- revision changed from r98 to r104