Bug #357
closedTC_LFR_UPDATE_TIME n'est pas correctement prise en compte
0%
Description
Test joué:
/home/validation/SCRIPT/long_timeissue_normal.py
Objectif du test
Envoi d'un TC_LFR_UPDATE_TIME avec CP_RPW_TIME=0x1b45fd970000 suivi du timecode 300ms apres, on obtient sur le TM_LFR_HK, la valeur TIME=0x83018d974fad.
09:35:48.460875, * 32 , *TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=117, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x800000024253,
09:35:48.774069, TC_LFR_UPDATE_TIME, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=11, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=1, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=1, SERVICE_TYPE: TIME_MANAGEMENT = 9, SERVICE_SUBTYPE: UPDATE_TIME = 129, SOURCE_ID: MISSION_TIMELINE = 110, CP_RPW_TIME=0x1b45fd970000, CRC = 0x44f1
09:35:49.460849, * 32 , *TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=1, (PACKET_SEQUENCE_CONTROL=0xc001), PACKET_LENGTH=117, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, T*IME=0x80000003424d*,
09:35:50.460926, * 32 , *TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=2, (PACKET_SEQUENCE_CONTROL=0xc002), PACKET_LENGTH=117, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x83018d974fad,
---------------------------------------------------------------
Contexte
LFR_FSW_PATH = /opt/LFR-FSW/2.0.1.1/fsw
Bridge selection = StarDundee
SocExplorerEngine.getSocExplorer: Version = 0.2.2, Branch = default, Changeset = c839740ef520
Carte EM
VHDL: 1.1.26