584 Bug Closed Normal [QR R3] [RPWSWR-621] : discussions internes sur CWF_F3 ACQ_TIME = 0x0000000 bruno katra 27/01/2017 02:20 PM Actions
362 Bug Closed High CWF_F3 : Champ PA_LFR_ACQUISITION_TIME=0x000000000000 bruno katra 27/01/2017 02:31 PM Actions
580 Bug Closed Normal [QR R3] [RPWSWR-633] : signer les documents bruno katra 27/01/2017 02:38 PM Actions
89 Bug Closed Low Attente de la première TM_LFR_SCIENCE_BURST_CWF_F2/TM_LFR_SCIENCE_NORMAL_SWF_Fx supérieure à sa période bruno katra 27/01/2017 02:42 PM Actions
862 Bug Closed Urgent Valeurs des masques RW erronées dans TM_LFR_PARAMETER_DUMP bruno katra 02/02/2017 03:55 PM Actions
910 Bug Closed Normal HK_LFR_DPU_SPW_LINK_STATE: ERROR_WAIT = 1 Veronique bouzid 03/02/2017 10:17 AM Actions
912 Bug Closed Normal champ HK_LFR_SC_POTENTIEL_FLAG passe à OFF Veronique bouzid 03/02/2017 10:55 AM Actions
911 Bug Closed Normal champ HK_LFR_PAS_FILTER_ENABLED non mis à jour apres envoi TC_LFR_LOAD_FILTER_PAR Veronique bouzid 03/02/2017 11:02 AM Actions
62 Bug Closed Normal Mise à jour ICD Veronique bouzid 03/02/2017 11:26 AM Actions
657 Bug Closed Immediate HK_LFR_xE_CNT doesn't manage the wrap of 8bits counter error Veronique bouzid 06/02/2017 10:49 AM Actions
947 Bug Closed Normal coquille output HK bruno katra 02/03/2017 10:31 AM Actions
934 Bug Closed Normal HK_LFR_SC_RW1_F1_FLAG not updated when RW1_F1 is set Veronique bouzid 02/03/2017 11:39 AM Actions
957 Bug Closed Normal Erroneous PA_LFR_RW_MASK_F2_WORD2 on TM_LFR_PARAMETER_DUMP when RW Freq = 96.0hz Veronique bouzid 03/03/2017 05:10 PM Actions
976 Bug Closed Urgent HK_LFR_SC_V_F3 is erroneous Veronique bouzid 16/03/2017 11:22 AM Actions
981 Bug Closed Immediate TC_LFR_LOAD_FILTER_PAR not acknowledged Veronique bouzid 17/03/2017 05:22 PM Actions
972 Bug Closed High Negative Parameters send into TC_LFR_LOAD_FILTER_PAR not rejected Veronique bouzid 17/03/2017 06:11 PM Actions
988 Bug Closed Urgent TC_LFR_LOAD_FILTER_PAR : filtrage erronée en cas de TBAD ou SHIFT non entier. paul leroy 20/03/2017 11:06 AM Actions
984 Bug Closed Immediate FFT retirée alors que en dehors du TBAD paul leroy 20/03/2017 11:19 AM Actions
978 Bug Closed Urgent Mauvais nombre de FFT retiré lors du filtrage PAS paul leroy 20/03/2017 11:22 AM Actions
939 Bug Closed Normal Negative RW Frequency send into TC_LFR_UPDATE_INFO is taken in account Veronique bouzid 20/03/2017 12:48 PM Actions
245 Bug Closed Normal synchronisation des snapshots bruno katra 24/03/2017 11:55 AM Actions
112 Bug Closed High Pb de traitement de TC_LFR_UPDATE_TIME bruno katra 24/03/2017 12:00 PM Actions
1005 Bug Closed High HK_LFR_SC_V_F3 , HK_LFR_SC_E1_F3 , HK_LFR_SC_E2_F3 see a differentnoise signal paul leroy 27/03/2017 03:56 PM Actions
982 Bug Closed Urgent Verification SC_potention V_F3 thomas chust 27/03/2017 03:57 PM Actions
1033 Bug Closed Urgent Moyennage à 16Hz dans les HK : nouveau filtre IIR implémenté donne des valeurs erronées Alexis Jeandet 28/03/2017 04:14 PM Actions