INSTRU: Issueshttps://hephaistos.lpp.polytechnique.fr/redmine/https://hephaistos.lpp.polytechnique.fr/redmine/redmine/favicon.ico?15080976012024-01-19T18:00:30ZRedmine
Redmine JUICE-SCM/Ground Segment - Task #4265 (Resolved): Add a system that allows to handle data without...https://hephaistos.lpp.polytechnique.fr/redmine/issues/42652024-01-19T18:00:30ZTheo Stassen
<p>Before now, in the process, we add waveforms -> spectra -> plot of anything we want.<br />Now we have waveforms -> spectra (if we want to plot anything outside waveforms) -> plot anything we want</p> JUICE-SCM/Ground Segment - Task #4262 (Resolved): Add multiple pytests (init, extract, display)https://hephaistos.lpp.polytechnique.fr/redmine/issues/42622024-01-12T17:46:43ZTheo StassenJUICE-SCM/Ground Segment - Task #4260 (Resolved): Add documentation handle in pre commit hookshttps://hephaistos.lpp.polytechnique.fr/redmine/issues/42602024-01-12T17:45:14ZTheo Stassen
<p>Now the pre commit check if the documentation creation works</p> JUICE-SCM/Ground Segment - Task #4230 (Resolved): Add a check if we don't find cdfs in the time l...https://hephaistos.lpp.polytechnique.fr/redmine/issues/42302023-11-21T17:51:14ZTheo StassenJUICE-SCM/Ground Segment - Task #4172 (Resolved): Adapt the calibration / evaluation code to allo...https://hephaistos.lpp.polytechnique.fr/redmine/issues/41722023-09-18T12:07:46ZTheo Stassen
<p>-Done during sweden week. As the Juice files has some differences with MMS files, lot of little adaptations needed.<br />-Debug of the incorrect epoch array computation (from the David Pisa code) -> now the data handle/quicklook of juice files is correct<br />-We can run the calibration code for Juice files, for now the calibration function list is empty.<br />-We can quicklook Juice files correctly (but need comparison with matlab code)</p> JUICE-SCM/Ground Segment - Task #4171 (Resolved): Add buttons to change the content structhttps://hephaistos.lpp.polytechnique.fr/redmine/issues/41712023-09-18T12:02:07ZTheo Stassen
<p>works, but when the content is changed, the plot is not interactive anymore -> need to find a solution</p> JUICE-SCM/Ground Segment - Task #4133 (Resolved): Adapt the matlab code for cdf data extraction (...https://hephaistos.lpp.polytechnique.fr/redmine/issues/41332023-07-03T14:56:08ZTheo Stassen
<p>We use Jan Soucek code for extract data of JUICE SID7 cdf, as base for our extraction of cdf content in the case of JUICE files<br />- Problem is that output of the matlab function doesn't seems to match what we need <del>> we will see<br /></del> Seems to have errors in matlab code, in progress</p> JUICE-SCM/Ground Segment - Task #4120 (Resolved): Add documentation on all code parametershttps://hephaistos.lpp.polytechnique.fr/redmine/issues/41202023-06-19T15:45:12ZTheo Stassen
<p>For each parameter used in the code for now, document it in config handler section, in order to have all doc at the same place</p> JUICE-SCM/Ground Segment - Task #4117 (Resolved): Adapt the code to have correct visual reprentat...https://hephaistos.lpp.polytechnique.fr/redmine/issues/41172023-06-15T16:33:48ZTheo Stassen
<p>When there are big holes in data the waveforms and spectra didn't match visually.<br />After lot of research and experiments, it seems that it is a bug of pcolormesh, so in a case of modes with big holes, we will prefer contourf.<br />The choice of the colorplot type is now modular</p> JUICE-SCM/Ground Segment - Task #4116 (Resolved): Adapt the code to use SCHB modehttps://hephaistos.lpp.polytechnique.fr/redmine/issues/41162023-06-15T16:30:43ZTheo Stassen
<p>Code modified/corrected to allow different modes -> SCHB mode now<br />tested. works well in the mathematical results, but visual problems with plots, spectra and waveforms don't match <br />visually</p> JUICE-SCM/Ground Segment - Task #4112 (Resolved): Add freq samp deducing function in deduce param...https://hephaistos.lpp.polytechnique.fr/redmine/issues/41122023-06-09T16:41:45ZTheo Stassen
<p>This step revealed that freq samp used in IDL was different than expected (not rounded) -> now that we compute freq samp the same way, results are even better ! 1e-7 of error instead of 1e-5</p> LFR-FSW - Task #3985 (Feedback): Test du chargement forcé des KCOEFF par défaut : écrasement des ...https://hephaistos.lpp.polytechnique.fr/redmine/issues/39852022-10-12T15:44:31Zbruno katra
<p>Demande de Thomas (mails du 11/10/2022) :</p>
<p>Hello Bruno,</p>
<p>As-tu le fichier des kcoeff correspondant au kcoef par defaut ? On pourrait déjà commencer par vérifier que cela marche, comme avec les valeurs par défaut (cohérence entre les SWF et les ASM). Non ?</p>
<p>Thomas</p>
<p>Voici ce que j'enverrais à Diane. C'est dans le même format que le fichier que je t'avais fourni pour le cas des kcoeff unitaires. Par rapport à ce que j'avais déjà produit au moment de la définition des kcoeff par défaut pour Alexis (fichiers datant du 2021-09-08), j'ai juste rajouté 3 décimales supplémentaires.</p>
<p>Thomas</p> Panneau_Leds_Antoine_MathieuF - Task #3610 (Feedback): JE DEMANDE AUX DEVELOPPEURS DE REGULIEREME...https://hephaistos.lpp.polytechnique.fr/redmine/issues/36102021-01-19T09:49:05Zantoine couvertSciQLOP - Task #2460 (Feedback): Augmentation des marges lors du drop d'une variablehttps://hephaistos.lpp.polytechnique.fr/redmine/issues/24602017-12-06T10:25:29ZAnonymousSolar Orbiter LFR - Task #18 (Feedback): PPBI et programmation des FPGAhttps://hephaistos.lpp.polytechnique.fr/redmine/issues/182013-12-03T09:19:00Zpaul leroy
<p>Comment mettre en oeuvre la stratégie de PPBI simplifié proposée par le CNES: mesure de performance à 3 températures, T_MAX (op = ), T_min et T_ambiante. Ceci implique:<br />=> choix d'un sous traitant qualifié<br />=> définition d'une solution pour la mise en oeuvre (résistance thermique du socket avec élastomère?)</p>
<p>Au niveau ESA: vérification de l'environnement de programmation + tests électriques après programmation.</p>
<p>Comment gérer la programmation des FPGAs?</p>
<p>Impossible de demander une livraison des pièces déjà programmées => programmation ultérieure</p>
<p>Note:<br />Operating Qualification (ON) -30°C +75°C<br />Operating Acceptance (ON) -25°C +70°C</p>