*METTRE A JOUR LA SRS AVEC LA REPONSE DE PHILIPPE* 

 --------------------------------- 

 
 le champ HK_LFR_MAG_FIELDS_FLAG est codé sur sur 1 bit. Au démarrage de LFR HK_LFR_MAG_FIELDS_FLAG = 0 

 Paul me précise qu il est mis à jour quand les données magnétiques sont présentes (SY_LFR_N_CWF_LONG_F3=1). 

 J'utilise le script /opt/VALIDATION_R3/lfrverif/LFR_SVS/SVS-0029/normal_mode_parameter_set.py 

 Ici la trace 
 17:57:17.849348, *TM_LFR_PARAMETER_DUMP*, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: DUMP = 6, (PACKET_ID=0xcc6), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=6, (PACKET_SEQUENCE_CONTROL=0xc006), PACKET_LENGTH=77, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: PARAMETER_DUMP = 32, DESTINATION_ID: GROUND = 0, TIME=0x80001533aa3b, PA_LFR_HK_SID: LFR_DUMP_SID = 10, SPARE=0x0, SY_LFR_BW=1, SY_LFR_SP0=0, SY_LFR_SP1=0, SY_LFR_R0=0, SY_LFR_R1=0, SY_LFR_R2=0, SY_LFR_N_SWF_L=2048, /!\SY_LFR_N_SWF_P=65535(s), SY_LFR_N_ASM_P=65535(s), SY_LFR_N_BP_P0=255(s), SY_LFR_N_BP_P1=255(s), SPARE=0x0, *SY_LFR_N_CWF_LONG_F3=1*, SPARE=0x0, SY_LFR_B_BP_P0=1(s), SY_LFR_B_BP_P1=5(s), SY_LFR_S1_BP_P0=0.25(s), SY_LFR_S1_BP_P1=1(s), SY_LFR_S2_BP_P0=1(s), SY_LFR_S2_BP_P1=5(s), SY_LFR_FBINS_F0_WORD1=0xffffffff, SY_LFR_FBINS_F0_WORD2=0xffffffff, SY_LFR_FBINS_F0_WORD3=0xffffffff, SY_LFR_FBINS_F0_WORD4=0xffffffff, SY_LFR_FBINS_F1_WORD1=0xffffffff, SY_LFR_FBINS_F1_WORD2=0xffffffff, SY_LFR_FBINS_F1_WORD3=0xffffffff, SY_LFR_FBINS_F1_WORD4=0xffffffff, SY_LFR_FBINS_F2_WORD1=0xffffffff, SY_LFR_FBINS_F2_WORD2=0xffffffff, SY_LFR_FBINS_F2_WORD3=0xffffffff, SY_LFR_FBINS_F2_WORD4=0xffffffff, SPARE8_2=0x0 

 17:57:18.038364, *TC_LFR_ENTER_MODE (CP_LFR_MODE=1)*, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TC_PACKET = 1, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: PRIVATE_SCIENCE_OR_TELECOMMAND = 12, (PACKET_ID=0x1ccc), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=0, (PACKET_SEQUENCE_CONTROL=0xc000), PACKET_LENGTH=13, CCSDS_SECONDARY_HEADER_FLAG=0, PUS_VERSION = 1, ACK_EXECUTION_COMPLETION=1, ACK_EXECUTION_PROGRESS=0, ACK_EXECUTION_START=0, ACK_ACCEPTANCE=1, SERVICE_TYPE: EQ_CONFIGURATION = 181, SERVICE_SUBTYPE: ENTER_MODE = 41, SOURCE_ID: MISSION_TIMELINE = 110, SPARE=0, CP_LFR_MODE: NORMAL = 1, CP_LFR_ENTER_MODE_TIME=0x000000000000, CRC = 0xca9b 

 17:57:18.061269, *TM_LFR_TC_EXE_SUCCESS*, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: ACKNOWLEDGE = 1, (PACKET_ID=0xcc1), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=24, (PACKET_SEQUENCE_CONTROL=0xc018), PACKET_LENGTH=13, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: TELECOMMAND_VERIFICATION = 1, SERVICE_SUBTYPE: TC_EXECUTION_COMPLETION_SUCCESS = 7, DESTINATION_ID: MISSION_TIMELINE = 110, TIME=0x80001533e0f4, PA_RPW_TELECOMMAND_PKT_ID=0x1ccc, PA_RPW_PKT_SEQ_CONTROL=0xc000 

 17:57:18.385053, TM_LFR_HK, CCSDS_VERSION_NUMBER = 0, PACKET_TYPE: TM_PACKET = 0, DATA_FIELD_HEADER_FLAG: WITH_HEADER = 1, PROCESS_ID: RPW_PID_2 = 76, PACKET_CATEGORY: HK_ROUTINE = 4, (PACKET_ID=0xcc4), SEGMENTATION_GROUPING_FLAG: STANDALONE_PACKET = 3, SEQUENCE_CNT=5426, (PACKET_SEQUENCE_CONTROL=0xd532), PACKET_LENGTH=129, SPARE_1=0, PUS_VERSION = 1, SPARE_2=0, SERVICE_TYPE: HOUSEKEEPING_AND_DIAGNOSTIC_DATA_REPORTING = 3, SERVICE_SUBTYPE: HK_PARAMETER_REPORT = 25, DESTINATION_ID: GROUND = 0, TIME=0x8000153433da, PA_LFR_HK_REPORT_SID: LFR_HK_SID = 1, HK_LFR_MODE: NORMAL = 1, HK_LFR_DPU_SPW_ENABLED: ENABLED = 1, HK_LFR_DPU_SPW_LINK_STATE: RUN = 5, SPARE=0x0, HK_LFR_SC_POTENTIEL_FLAG: ON = 1, *HK_LFR_MAG_FIELDS_FLAG: OFF = 0*,  

 Ce champ n'est jamais mis à jour car pas pris en compte. 

 le fichier de trace est dans /home/validation/data/R3/3.0.0.8/1.1.88/SVS-0029/2015_07_28-18_32_00-Detail.txt 

 Contexte du test 
 ---------------- 
 FSW 3.0.0.8 
 VHDL 1.1.88 
 EM sans Timegen 
 SocExplorerEngine.getSocExplorer: Version = 0.6.2, Branch = default, Changeset = 819d0376d481 