Bug #981
closed
TC_LFR_LOAD_FILTER_PAR not acknowledged
Added by Veronique bouzid over 6 years ago.
Updated over 6 years ago.
Description
Le script utilisé est /home/validation/SCRIPT/R3++/set_load_filter_par.py.
L'envoi d une TC_LFR_LOAD_FILTER_PAR n est pas acquittée
09:56:29.206898,/home/validation/SCRIPT/R3++/set_load_filter_par.py
09:56:31.208759,PROXY LOAD is True
09:56:45.225339, /!\No TM_LFR_TC_EXE_* after time-out (4s).
09:56:50.226504, /!\No TM_LFR_TC_EXE_* after time-out (4s).
09:57:02.227914, /!\No TM_LFR_TC_EXE_* after time-out (4s).
09:57:07.228961, /!\No TM_LFR_TC_EXE_* after time-out (4s).
09:57:12.229741,End(/home/validation/SCRIPT/R3++/set_load_filter_par.py)
Les fichiers de données (2017_03_16-09_57_12*) sont rangés dans /home/validation/data/R3++/3.2.0.3/1.1.91/TEST-UNITAIRES/set_load_filter_par.
Contexte du test
----------------
FSW 3.2.0.3
VHDL 1.1.91
EM1 sans Timegen
SocExplorerEngine.getSocExplorer: Version = 0.7.0, Branch = 0.6, Changeset = c459540a6dbd+
StarDundee
- Subject changed from TC_LFR_LOAD_FILTER_PAR not ackknowledged to TC_LFR_LOAD_FILTER_PAR not acknowledged
- Description updated (diff)
Essai d'envoi de TC_LOAD_FILTER_PAR à partir de mon banc de test :
la tc n'est pas acquitée ET le GSE ne montre plus d'activité : perte du lien SpW et eimpossible de se reconnecter.
Contexte du test
----------------
FSW 3.2.0.3
VHDL 1.1.91
EM1 AVEC Timegen
StarDundee
- Status changed from New to Resolved
- Assignee changed from paul leroy to Veronique bouzid
Reprise de la fonction et test avec un script python et socexplorer sur certaines valeurs des paramètres. Le logiciel ne plante plus suite à quelques modifications, bien que je n'aie pas vraiment compris l'origine du problème. Les valeurs de k négatives entrainent un rejet de la télécommande. Pas de borne MAX de définie.
fsw >= 3.2.0.4
- Status changed from Resolved to Closed
Also available in: Atom
PDF